Date published: 2025-9-9

001 800-1338-3838

SCBT Portrait Logo
Seach Input

SREBP-1 항체 (E-4): sc-17755

4.6(8)
리뷰 쓰기질문하기

데이터 시트
  • SREBP-1 항체(E-4) 는 마우스 monoclonal IgG2bκ, 15간행물에 인용, 이며 200 µg/ml으로 제공합니다.
  • human origin의 SREBP-1에서 내부에 위치한 41-200 아미노산을 항원으로 사용하였습니다.
  • 안티-SREBP-1 항체 (E-4)는 WB, IP, IF, IHC(P) and ELISA으로 mouse, rat and human유래의 SREBP-1 를 감지하는 데에 추천한다.
  • 항-SREBP-1 항체(E-4)는 IP용 agarose와 결합되어 이용 가능하며, WB, IHC(P), ELISA용 HRP와 결합되어 이용 가능하며, IF, IHC(P), FCM용 phycoerythrin 또는 FITC와 결합되어 이용 가능합니다.
  • WB (RGB), IF, IHC(P) 와FCM, RGB fluorescent imaging systems, such as iBright™ FL1000, FluorChem™, Typhoon, Azure and other comparable systems에 사용가능한 Alexa Fluor® 488, Alexa Fluor® 546, Alexa Fluor® 594 or Alexa Fluor® 647결합제품도 있습니다.
  • WB (NIR), IF와FCM,Near-Infrared (NIR) detection systems, such as LI-COR®Odyssey®, iBright™ FL1000, FluorChem™, Typhoon, Azure and other comparable systems에 사용가능한 Alexa Fluor® 680 or Alexa Fluor® 790 결합제품도 있습니다.
  • Gel Supershift와 ChIP 에 사용하는 TransCruz시약(sc-17755 X, 200 µg/0.1 ml)이 있습니다.
  • SREBP-1 (E-4): sc-17755무료10 µg 샘플을 신청하려면 기술지원팀 (또는 로컬 디스트리뷰터)에 연락주세요.
  • m-IgG Fc BP-HRPm-IgG2b BP-HRP 는 SREBP-1 항체 (E-4) 가 WB and IHC(P) 에 응용될 때 우선으로 사용하는 이차 항체 검사 시약입니다.이 시약은SREBP-1 항체(E-4) 와 세트로 제공드립니다. (아래의 주문 정보를 참고해 주시길 바랍니다).

빠른 링크

더보기

SREBP-1 항체(E-4)는 웨스턴 블롯(WB), 면역침전(IP), 면역형광(IF), 면역조직화학(IHC), 효소결합면역흡착분석(ELISA) 등의 방법을 통해 쥐, 쥐, 인간에서 유래된 SREBP-1 단백질을 검출하는 쥐 단일클론 IgG2b 카파 경쇄 항체입니다. SREBP-1(E-4) 항체는 비접합 형태와 아가로스, 호스래디시 퍼옥시다아제, 피코에리트린, 플루오레세인 이소티오시아네이트, 다중 알렉사 플루오르® 접합체를 포함한 다양한 접합체 형태로 제공됩니다. SREBP-1 단백질은 콜레스테롤과 지방산 합성에 관여하는 유전자의 발현을 조절함으로써 지질 대사에 중요한 역할을 합니다. SREBP-1 단백질은 핵막과 소포체에 존재하는 전구체로 합성되며, 스테롤이 고갈되면 단백질 분해 절단을 거쳐 핵으로 이동하는 가용성 단편을 방출하여 저밀도 지단백질 수용체를 포함한 표적 유전자의 전사를 활성화합니다. 이 수용체는 콜레스테롤을 운반하는 지단백질의 세포내 흡수를 위해 필수적이며, 따라서 세포 및 혈장 콜레스테롤 수치를 유지합니다. 과도한 콜레스테롤은 세포 기능 장애를 유발하고 죽상동맥경화증과 같은 질병의 원인이 될 수 있기 때문에 SREBP-1 조절은 세포 항상성에 필수적입니다.

연구용으로만 사용가능합니다. 진단이나 치료용으로 사용불가합니다.

Alexa Fluor®는 미국 오리건주 Molecular Probes Inc.의 상표입니다.

LI-COR®와 Odyssey®는 LI-COR Biosciences의 등록 상표입니다.

주문정보

제품명카탈로그 번호 단위가격수량관심품목

SREBP-1 항체 (E-4)

sc-17755
200 µg/ml
$316.00

SREBP-1 (E-4): m-IgG Fc BP-HRP 번들

sc-525483
200 µg Ab; 10 µg BP
$354.00

SREBP-1 (E-4): m-IgG2b BP-HRP 번들

sc-549567
200 µg Ab; 10 µg BP
$354.00

SREBP-1 항체 (E-4) X

sc-17755 X
200 µg/0.1 ml
$316.00

SREBP-1 항체 (E-4) AC

sc-17755 AC
500 µg/ml, 25% agarose
$416.00

SREBP-1 항체 (E-4) HRP

sc-17755 HRP
200 µg/ml
$316.00

SREBP-1 항체 (E-4) FITC

sc-17755 FITC
200 µg/ml
$330.00

SREBP-1 항체 (E-4) PE

sc-17755 PE
200 µg/ml
$343.00

SREBP-1 항체 (E-4) Alexa Fluor® 488

sc-17755 AF488
200 µg/ml
$357.00

SREBP-1 항체 (E-4) Alexa Fluor® 546

sc-17755 AF546
200 µg/ml
$357.00

SREBP-1 항체 (E-4) Alexa Fluor® 594

sc-17755 AF594
200 µg/ml
$357.00

SREBP-1 항체 (E-4) Alexa Fluor® 647

sc-17755 AF647
200 µg/ml
$357.00

SREBP-1 항체 (E-4) Alexa Fluor® 680

sc-17755 AF680
200 µg/ml
$357.00

SREBP-1 항체 (E-4) Alexa Fluor® 790

sc-17755 AF790
200 µg/ml
$357.00

Does this antibody identifies both mature and immature forms of SREBP1?

Asked by: Monteiro
Thank you for your question. This mouse monoclonal antibody was raised against amino acids 41-200 of SREBP-1 of human origin, but the antibody has not been epitope mapped so further information regarding the epitope location is not available at this time. In Western blot experiments the precursor form is most commonly detected with this antibody.
Answered by: Tech Service
Date published: 2020-01-30

When should the TransCruz reagent sc-17755 X be used instead of the standard form sc-17755?

Asked by: TinTin
Thank you for your question. We recommend using the TransCruz reagent form when performing ChIP or GelShift assays. This form can also be used in other applications such as Western Blot or IHC, but the dilution should be adjusted by a factor of 10 to account for the higher original concentration.
Answered by: Technical Support
Date published: 2017-02-24
  • y_2025, m_9, d_8, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_ko_KR, sid_17755, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 110ms
  • QUESTIONS, PRODUCT
Rated 5 out of 5 by from Excellent antibodyIt is highly sensitive antibody, with very little background.
Date published: 2018-07-31
Rated 4 out of 5 by from Overall OKI used 1:500. For some reason can't see in A549 (even with longer exposion). Supposed size should be 125 (135) KD, but H1299 is about 150KD, and A549 have light band about 200KD? Not consider A549 can visualize bands. H1299 have a light band at around 80KD. Not sure what are they
Date published: 2017-05-23
Rated 5 out of 5 by from Versatile AntibodyThis antibody is well-cited for a variety of applications including WB, IP, IF, and even IHC and ELISA. Strong, clear signal with little to no background. Beautiful tissue staining. Works well in a variety of species including mouse, rat, and human samples.
Date published: 2017-01-25
Rated 4 out of 5 by from WB data obtained when using this antibodyWB data obtained when using this antibody on HeLa nuclear extract. -SCBT QC
Date published: 2015-04-29
Rated 5 out of 5 by from Good WB publishable data gathered with ratGood WB publishable data gathered with rat liver hepatocytes. -SCBT Publication Review
Date published: 2015-04-15
Rated 5 out of 5 by from Strong signal in human SREBPStrong signal in human SREBP-1 transfected 293T whole cell lysate. -SCBT QC
Date published: 2015-02-28
Rated 4 out of 5 by from Publishable data obtained via ChIP on HepG2 cellsPublishable data obtained via ChIP on HepG2 cells. -SCBT Publication Review
Date published: 2015-01-22
Rated 5 out of 5 by from Publishable IHC staining with paraffinPublishable IHC staining with paraffin-embedded human SZ95 seboytes. -SCBT QC
Date published: 2013-11-11
  • y_2025, m_9, d_8, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_8
  • loc_ko_KR, sid_17755, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 17ms
  • REVIEWS, PRODUCT
SREBP-1 항체 (E-4) is rated 4.6 out of 5 by 8.
  • y_2025, m_9, d_8, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_8
  • loc_ko_KR, sid_17755, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 108ms
  • REVIEWS, PRODUCT