His-Tag Anticuerpo (H-3) recomendado para detectar fusion proteins encoded by polyhistidine expression vectors medainte WB y IP

His-Tag Anticuerpo (H-3): sc-8036

His-Tag Anticuerpo (H-3) clasificado 4.6 de 5 por 40.
  • y_2020, m_9, d_23, h_15
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_40
  • loc_es_ES, sid_8036, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-3.2.0
  • CLOUD, getAggregateRating, 145ms
  • REVIEWS, PRODUCT
5
31
4
5
3
1
2
2
1
1

Ficha técnica

    • Anti-His-Tag Anticuerpo H-3 es un monoclonal de ratón IgG1 (kappa light chain) His-Tag Anticuerpo proporcionado como 200 µg/ml
    • raised against a His-tagged recombinant protein
    • His-Tag Anticuerpo (H-3) es recomendado para detectar fusion proteins encoded by polyhistidine expression vectors medainte WB y IP
    • His-Tag Anticuerpo (H-3) es disponible conjugado a agarosa para IP; HRP para WB, IHC(P) y ELISA; y tanto a phycoerythrin como a FITC para IF, IHC(P) y FCM
    • también disponible conjugado a Alexa Fluor® 488, Alexa Fluor® 546, Alexa Fluor® 594 o Alexa Fluor® 647 para WB (RGB), IF, IHC (P) y FCM
    • también disponible conjugado a Alexa Fluor® 680 o Alexa Fluor® 790 para WB (NIR), IF y FCM
    • también disponibles conjugados a biotina para WB, IHC(P) y ELISA
    • Ver m-IgGκ BP-HRP (mouse IgGκ binding protein-HRP), nuestras altamente recomendadas alternativa a los anticuerpos secundarios convencionales, anti-IgG de ratón.
    • Contacte con nosotros para recibir GRATIS 10 µg de muestra de His-Tag (H-3): sc-8036.

I'd like to know this Ab is working both N-terminal and C-terminal 6xHis ?

Preguntado por: Hiroki
Thank you for your question. This antibody was raised against a His tagged recombinant protein. Unfortunately the exact epitope has not been mapped, so we do not have further information.
Respondida por: Tech Service
Fecha de publicación: 2019-08-21

What buffer should i use to dilute the antibody? can the antibody be stored in that buffer?

Preguntado por: yanale
Thank you for your question. This depends on the application you are using the antibody for, so it is difficult to answer. For Western blotting we recommend 5% milk with TBS-T, and for IHC we would recommend using a blocking serum or reagent. You can find this information in our recommended protocols which you can find here: https://www.scbt.com/scbt/resources/protocols
Respondida por: Tech Service
Fecha de publicación: 2019-04-29

Can this antibody pick up 10His-tagged proteins?

Preguntado por: wei UTHSC
Thank you for your question. We have not tested this antibody for the detection of 10-His-tagged proteins, but it is possible that it would work fine. If you have any further questions, please contact Technical Service.
Respondida por: Tech Service
Fecha de publicación: 2019-02-25

What is the volume provided of this antibody? I noticed that you don't provide final volume for any of your anti-HIS antibodies. Are all your antibody prices for a specific amount?

Preguntado por: Labrat
Thank you for your question. We provide a total of 200 µg IgG in 1 ml final volume. Pricing is available on our website.
Respondida por: Technical Support
Fecha de publicación: 2019-02-23

Hi, for the His-probe Antibody (H-3): sc-8036. If I want to use it in a ELISA assay, what is the recommend concentration? Thank you

Preguntado por: Jackie1029
Thank you very much for your question. We suggest this antibody at a starting dilution of 1:50 to test antibody samples and controls at 50 µl/well diluted in blocking buffer. Antibodies may be serially diluted for determining the titer. Our ELISA protocol: https://www.scbt.com/scbt/resources/protocols/elisa-assays
Respondida por: Technical Support Europe
Fecha de publicación: 2018-01-11

Thank you very much for the below comments on using these Ab for ELISA. So what is the recommended dilution that I can start with ?

Preguntado por: Oleg
Thank you for your question. We would recommend starting with a high concentration of antibody, or a 1:100 dilution, but we recommend optimizing for the best antibody to antigen concentration through titration. A link to our recommended protocol is below. https://www.scbt.com/scbt/resources/protocols/elisa-assays
Respondida por: Technical Support
Fecha de publicación: 2017-11-06

Hello, I am wondering if these Ab can be used for ELISA? -if yes, what is the recommended dilution? if not, what His Ab are recommended -and what secondary Ab conjugated to HRP can you recommend ? Thank you Kind regards Oleg Tyurin

Preguntado por: Oleg
Thank you for your question. Yes, you can use this mouse monoclonal antibody, His-probe (H-3): sc-8036, for ELISA. This primary antibody is a mouse monoclonal IgG1 so you could use any anti-mouse IgG secondary antibody for detection. We recommend using our mouse IgG kappa binding protein (m-IgGκ BP) conjugated to Horseradish Peroxidase (HRP): sc-516102. A link is provided below as a reference. https://www.scbt.com/scbt/product/m-igg-kappa-bp-hrp
Respondida por: Technical Support
Fecha de publicación: 2017-11-02

Does sc-8036 AF488 contain a vial of His Peptide, in addition to the probe? Tx.

Preguntado por: Goenuel
Thank you for your question. We do not sell a corresponding blocking peptide to be used in conjunction with this mouse monoclonal His-probe Antibody (H-3): sc-8036.
Respondida por: Technical Support
Fecha de publicación: 2017-09-20
  • y_2020, m_9, d_23, h_15CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_11
  • loc_es_ES, sid_8036, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-3.2.0
  • CLOUD, getContent, 149ms
  • QUESTIONS, PRODUCT
Rated 5 de 5 por de Works perfectly in Western Blot Used His-probe H-3 HRP for detection of His-tagged protein as 1:500 dilution in 1xTBST/5% skim milk over night at 4°C
Fecha de publicación: 2019-07-09
Rated 5 de 5 por de Sehr gute Ergebnisse im WB und ELISA. Sehr gute Ergebnisse im WB und ELISA. Sehr zufrieden.
Fecha de publicación: 2019-07-05
Rated 5 de 5 por de Excellent Highly specific, strong bands, dilution in WB used 1:5000.
Fecha de publicación: 2018-10-23
Rated 5 de 5 por de Muy buenos resultados Encantados con los resultados y con el servicio prestado por la empresa
Fecha de publicación: 2018-04-12
Rated 2 de 5 por de Poor signal I tried a 10 ug sample of His probe antibody to detect 6 His tagged protein. A 1:100 dilution was used including overnight incubation. Alkaline-phosphatase linked second antibody was used. 50 ug of his-tagged protein was added. The signal was very poor.
Fecha de publicación: 2018-03-26
Rated 5 de 5 por de Great features I bought this a month ago and am so happy that I did
Fecha de publicación: 2018-02-05
Rated 5 de 5 por de Very Clean Antibody! Gave strong signal on WBs for His tagged proteins expressed in insect cells.
Fecha de publicación: 2018-01-31
Rated 4 de 5 por de Good results The is a good antibody to recognize his tag products.
Fecha de publicación: 2017-12-12
  • y_2020, m_9, d_23, h_15
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_40
  • loc_es_ES, sid_8036, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-3.2.0
  • CLOUD, getReviews, 36ms
  • REVIEWS, PRODUCT

Santa Cruz Biotechnology, Inc. es un líder mundial en el desarrollo de productos para el mercado de la investigación biomédica. Llámenos gratis al 00 800 4573 8000.
Copyright © 2007-2020 Santa Cruz Biotechnology, Inc. All Rights Reserved."Santa Cruz Biotechnology", y el logo de Santa Cruz Biotechnology, Inc., "Santa Cruz Animal Health", "San Juan Ranch", "Supplement of Champions", el logo de San Juan Ranch, "Ultracruz", "Chemcruz", "Immunocruz", "Exactacruz", y "EZ Touch" son marcas registradas de Santa Cruz Biotechnology, Inc. Todas las marcas registradas son propiedad de su respectivo dueño.