Datasheets
  • Siglec-7 Antibody (F-2) is a mouse monoclonal IgG1 κ provided at 200 µg/ml
  • raised against amino acids 407-454 mapping near the C-terminus of Siglec-7 of human origin
  • recommended for detection of Siglec-7 of human origin by WB, IP, IF and ELISA
  • m-IgG Fc BP-HRP, m-IgG1 BP-HRP and m-IgGκ BP-HRP are the preferred secondary detection reagents for Siglec-7 Antibody (F-2) for WB applications. These reagents are now offered in bundles with Siglec-7 Antibody (F-2) (see ordering information below).
    Gene Editing Promo Banner

    QUICK LINKS

    SEE ALSO...

    Siglec-7 Antibody (F-2) is a mouse monoclonal IgG1 antibody that detects Siglec-7 in human samples through applications such as western blotting (WB), immunoprecipitation (IP), immunofluorescence (IF), and enzyme-linked immunosorbent assay (ELISA). Siglec-7 is a member of the sialic acid-binding immunoglobulin superfamily and plays a crucial role in modulating immune responses, particularly in the inhibition of natural killer (NK) cell cytotoxicity. This function is vital for maintaining immune homeostasis and preventing excessive tissue damage during immune responses. Siglec-7 is predominantly expressed in monocytes and resident blood cells, but expression is notably absent in parenchymatous cells, highlighting a specialized role in immune regulation. The interaction of Siglec-7 with sialylated ligands on target cells can lead to the downregulation of NK cell activity, which is essential for controlling immune responses against tumors and viral infections. The ability of Siglec-7 to mediate these interactions underscores importance in both innate and adaptive immunity, making Siglec-7 a significant target for research in immunology and therapeutic interventions. Anti-Siglec-7 antibody (F-2) is an invaluable tool for researchers aiming to explore the complex mechanisms of immune regulation and the potential therapeutic applications of modulating Siglec-7 activity.

    For Research Use Only. Not Intended for Diagnostic or Therapeutic Use.

    Alexa Fluor® is a trademark of Molecular Probes Inc., OR., USA

    LI-COR® and Odyssey® are registered trademarks of LI-COR Biosciences

    Siglec-7 Antibody (F-2) References:

    1. Siglec-7 tetramers characterize B-cell subpopulations and leukemic blasts.  |  Gieseke, F., et al. 2012. Eur J Immunol. 42: 2176-86. PMID: 22585296
    2. Siglec-7 as a Novel Biomarker to Predict Mortality in Decompensated Cirrhosis and Acute Kidney Injury.  |  Allegretti, AS., et al. 2016. Dig Dis Sci. 61: 3609-3620. PMID: 27655105
    3. DNA methylation-mediated Siglec-7 regulation in natural killer cells via two 5' promoter CpG sites.  |  Huang, HT., et al. 2020. Immunology. 160: 38-51. PMID: 32027025
    4. Reduced Siglec-7 expression on NK cells predicts NK cell dysfunction in primary hepatocellular carcinoma.  |  Tao, L., et al. 2020. Clin Exp Immunol. 201: 161-170. PMID: 32319079
    5. Identification and functional characterization of a Siglec-7 counter-receptor on K562 cells.  |  Yoshimura, A., et al. 2021. J Biol Chem. 296: 100477. PMID: 33640457
    6. Molecular Basis and Role of Siglec-7 Ligand Expression on Chronic Lymphocytic Leukemia B Cells.  |  Chang, LY., et al. 2022. Front Immunol. 13: 840388. PMID: 35711441
    7. Histone deacetylation-regulated cell surface Siglec-7 expression promoted megakaryocytic maturation and enhanced platelet-like particle release.  |  Huang, YF., et al. 2023. J Thromb Haemost. 21: 329-343. PMID: 36700509
    8. Tumor cell-intrinsic and tumor microenvironmental conditions co-determine signaling by the glycoimmune checkpoint receptor Siglec-7.  |  van Houtum, EJH., et al. 2023. Cell Mol Life Sci. 80: 169. PMID: 37253806
    9. Synthesis and Binding Mode Predictions of Novel Siglec-7 Ligands.  |  Frank, M., et al. 2023. J Med Chem. 66: 14315-14334. PMID: 37793071
    10. Sialylated glycoproteins suppress immune cell killing by binding to Siglec-7 and Siglec-9 in prostate cancer.  |  Wen, RM., et al. 2024. J Clin Invest. 134: PMID: 39436703

    Ordering Information

    Product NameCatalog #UNITPriceQtyFAVORITES

    Siglec-7 Antibody (F-2)

    sc-398181
    200 µg/ml
    $322.00

    Siglec-7 Antibody (F-2): m-IgG Fc BP-HRP Bundle

    sc-538387
    200 µg Ab; 10 µg BP
    $361.00

    Siglec-7 Antibody (F-2): m-IgGκ BP-HRP Bundle

    sc-535993
    200 µg Ab; 40 µg BP
    $361.00

    Siglec-7 Antibody (F-2): m-IgG1 BP-HRP Bundle

    sc-545677
    200 µg Ab; 20 µg BP
    $361.00

    What is the recommended starting dilution for Western blot for Siglec-7 (F-2): sc-398181 monoclonal antibody?

    Asked by: cjMara
    Thank you for your question. The recommended starting dilution for Western blot is 1:100 with a dilution range of 1:100-1:1000. This information, along with other technical specifications, can be found in the “datasheet” link at the top of the product page, for which I have provided the link: https://datasheets.scbt.com/sc-398181.pdf If you have any further questions or concerns, please contact our Technical Service department by calling 800-457-3801 option 2, emailing scbt@scbt.com, or using the Live Chat function on our website.
    Answered by: Technical Support
    Date published: 2017-03-01
    • y_2026, m_5, d_6, h_12CST
    • bvseo_bulk, prod_bvqa, vn_bulk_3.0.43
    • cp_1, bvpage1
    • co_hasquestionsanswers, tq_1
    • loc_en_US, sid_398181, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_scbt
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getContent, 168ms
    • QUESTIONS, PRODUCT
    Rated 5 out of 5 by from Satisfactory Western blot data of SiglecSatisfactory Western blot data of Siglec-7 expression in non-transfected and human Siglec-7 transfected 293T whole cell lysates. -SCBT QC
    Date published: 2014-01-20
    • y_2026, m_5, d_6, h_12
    • bvseo_bulk, prod_bvrr, vn_bulk_3.0.43
    • cp_1, bvpage1
    • co_hasreviews, tv_0, tr_1
    • loc_en_US, sid_398181, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_scbt
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getReviews, 17ms
    • REVIEWS, PRODUCT
    Siglec-7 Antibody (F-2) is rated 5.0 out of 5 by 1.
    • y_2026, m_5, d_6, h_12
    • bvseo_bulk, prod_bvrr, vn_bulk_3.0.43
    • cp_1, bvpage1
    • co_hasreviews, tv_0, tr_1
    • loc_en_US, sid_398181, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_scbt
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getAggregateRating, 94ms
    • REVIEWS, PRODUCT