Date published: 2025-9-7

001 800-1338-3838

SCBT Portrait Logo
Seach Input

Pol II 항체 (CTD4H8): sc-47701

4.4(28)
리뷰 쓰기질문하기

데이터 시트
  • Pol II 항체 CTD4H8 는 마우스 monoclonal IgG1 κ Pol II 항체, 112간행물에 인용, 이며 200 µg/ml으로 제공합니다.
  • 화학적으로 합성된 포스포세린(phospho-ser) 5를 사용하여 합성 펩타이드 YSPTSPS의 10개 반복에 대해 항체 생성
  • Pol II 항체 (CTD4H8)는 WB, IP, IF and IHC(P)으로 mouse, rat and human유래의 hypo- and hyper-phosphorylated Pol II 를 감지하는 데에 추천한다.
  • 항-Pol II 항체(CTD4H8)는 IP용 agarose와 결합되어 이용 가능하며, WB, IHC(P), ELISA용 HRP와 결합되어 이용 가능하며, IF, IHC(P), FCM용 phycoerythrin 또는 FITC와 결합되어 이용 가능합니다.
  • WB (RGB), IF, IHC(P) 와FCM, RGB fluorescent imaging systems, such as iBright™ FL1000, FluorChem™, Typhoon, Azure and other comparable systems에 사용가능한 Alexa Fluor® 488, Alexa Fluor® 546, Alexa Fluor® 594 or Alexa Fluor® 647결합제품도 있습니다.
  • WB (NIR), IF와FCM,Near-Infrared (NIR) detection systems, such as LI-COR®Odyssey®, iBright™ FL1000, FluorChem™, Typhoon, Azure and other comparable systems에 사용가능한 Alexa Fluor® 680 or Alexa Fluor® 790 결합제품도 있습니다.
  • Gel Supershift와 ChIP 에 사용하는 TransCruz시약(sc-47701 X, 200 µg/0.1 ml)이 있습니다.
  • Pol II (CTD4H8): sc-47701무료10 µg 샘플을 신청하려면 기술지원팀 (또는 로컬 디스트리뷰터)에 연락주세요.
  • m-IgG Fc BP-HRPm-IgG1 BP-HRP 는 Pol II 항체 (CTD4H8) 가 WB and IHC(P) 에 응용될 때 우선으로 사용하는 이차 항체 검사 시약입니다.이 시약은Pol II 항체(CTD4H8) 와 세트로 제공드립니다. (아래의 주문 정보를 참고해 주시길 바랍니다)

빠른 링크

더보기

Pol II 항체(CTD4H8)는 마우스, 쥐, 인간에서 유래된 Pol II 단백질을 웨스턴 블롯(WB), 면역침전(IP), 면역형광(IF), 면역조직화학(IHC)을 통해 검출하는 마우스 단일클론 IgG1 kappa 경쇄 항체입니다. 항폴II 항체(CTD4H8)는 비접합 형태와 아가로스, 과산화효소(HRP), 피코에리트린(PE), 플루오레세인 이소티오시아네이트(FITC), 다중 알렉사 플루오르® 접합체를 포함한 다양한 접합체 형태로 제공됩니다. RNA 폴리머라제 II(Pol II)는 단백질 코딩 유전자의 전사에 중요한 역할을 하며, Pol II의 기능은 유전자 발현 조절에 필수적입니다. 이 효소는 12개의 소단위로 구성되어 있으며, 가장 큰 소단위인 RPB1(RPB205라고도 함)은 1,840개의 아미노산으로 구성된 단백질로, C2H2형 아연 핑거와 헵타펩타이드 반복이 풍부한 C-말단 도메인을 특징으로 합니다. RPB1의 구조적 완전성은 필수적입니다. RPB1은 폴 II의 촉매 활성을 전달할 뿐만 아니라 전사 과정에 중요한 DNA 결합 도메인의 형성에 기여하기 때문입니다. RPB1과 다른 서브유닛 사이의 상호작용은 전사 기구가 표적 프로모터에 효과적으로 모집되어 mRNA 합성의 시작을 촉진하도록 합니다. 특히 가장 큰 서브유닛의 변형을 통해 폴 II 기능의 붕괴는 유전자 발현에 상당한 손상을 초래할 수 있으며, 이는 세포 기능과 발달에 있어 RPB1의 중요성을 강조합니다.

연구용으로만 사용가능합니다. 진단이나 치료용으로 사용불가합니다.

Alexa Fluor®는 미국 오리건주 Molecular Probes Inc.의 상표입니다.

LI-COR®와 Odyssey®는 LI-COR Biosciences의 등록 상표입니다.

주문정보

제품명카탈로그 번호 단위가격수량관심품목

Pol II 항체 (CTD4H8)

sc-47701
200 µg/ml
$316.00

Pol II (CTD4H8): m-IgG Fc BP-HRP 번들

sc-526732
200 µg Ab; 10 µg BP
$354.00

Pol II (CTD4H8): m-IgG1 BP-HRP 번들

sc-532105
200 µg Ab; 20 µg BP
$354.00

Pol II 항체 (CTD4H8) X

sc-47701 X
200 µg/0.1 ml
$316.00

Pol II 항체 (CTD4H8) AC

sc-47701 AC
500 µg/ml, 25% agarose
$416.00

Pol II 항체 (CTD4H8) HRP

sc-47701 HRP
200 µg/ml
$316.00

Pol II 항체 (CTD4H8) FITC

sc-47701 FITC
200 µg/ml
$330.00

Pol II 항체 (CTD4H8) PE

sc-47701 PE
200 µg/ml
$343.00

Pol II 항체 (CTD4H8) Alexa Fluor® 488

sc-47701 AF488
200 µg/ml
$357.00

Pol II 항체 (CTD4H8) Alexa Fluor® 546

sc-47701 AF546
200 µg/ml
$357.00

Pol II 항체 (CTD4H8) Alexa Fluor® 594

sc-47701 AF594
200 µg/ml
$357.00

Pol II 항체 (CTD4H8) Alexa Fluor® 647

sc-47701 AF647
200 µg/ml
$357.00

Pol II 항체 (CTD4H8) Alexa Fluor® 680

sc-47701 AF680
200 µg/ml
$357.00

Pol II 항체 (CTD4H8) Alexa Fluor® 790

sc-47701 AF790
200 µg/ml
$357.00

With what kind of magnetic beads these Abs work good for ChIP? I tried with Dynabeads Protein G and I didn't get it

Asked by: Asya
Thank you for your question. We have not specifically tested this antibody using magnetic beads, and we do not sell those type of magnetic beads so we can not make a recommendation. This is a mouse monoclonal IgG1, so we would recommend asking the magnetic bead supplier for their recommendation. This specific monoclonal antibody has been validated for ChIP (please refer to the product citations for more details).
Answered by: Technical Support
Date published: 2019-01-26

According to the info sheet, this antibody was RNAPII Ser5p specific, have you check the specificity against Ser2p/Ser7p or non phopsphorylated RNAPII?

Asked by: Babybear
Thank you for your question. This antibody is recommended for detection of hypo- and hyper-phosphorylated Pol II of mouse, rat and human origin.
Answered by: Tech Service
Date published: 2024-11-12

Can I use this mouse monoclonal antibody for IHC or IF staining on mouse samples?

Asked by: Anna99
Yes, this Pol II Antibody (CTD4H8): sc-47701 is available conjugated to agarose (sc-47701 AC), 500 µg/0.25 ml agarose in 1 ml, for IP; HRP (sc-47701 HRP), 200 µg/ml, for WB, IHC(P) and ELISA; phycoerythrin (sc-47701 PE), fluorescein (sc-47701 FITC), Alexa Fluor® 488 (sc-47701 AF488) or Alexa Fluor® 647 (sc-47701 AF647), 200 µg/ml, for IF, IHC(P) and FCM.
Answered by: Tech Service 5
Date published: 2017-01-05

Does the antibody specifically recognizes only Ser5-phosphorylated Pol II CTD? I would like to perform ChIP for total Pol II, as well as Ser5- and Ser2-phosphorylated Pol II. Would you recommend using this antibody as a control for total Pol II?

Asked by: Mauri
  • y_2025, m_9, d_7, h_4CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_ko_KR, sid_47701, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 110ms
  • QUESTIONS, PRODUCT
Rated 5 out of 5 by from works well for ChIPWorks well for ChIP and ChIP-seq (human MCF10A cells)
Date published: 2023-03-22
Rated 5 out of 5 by from Easy to UsePurchased this antibody for use in immunofluorescence and microscopy. Antibody worked well in a variety of concentrations and when paired with a secondary produced good images.
Date published: 2020-08-06
Rated 5 out of 5 by from worked greatat 1:1000 dilution the Western blot worked first time
Date published: 2019-11-01
Rated 4 out of 5 by from It works well for ChIPWe tried this antibody for ChIP on both isolated primary mouse hepatocytes and mouse livers, and it worked well!
Date published: 2019-07-07
Rated 4 out of 5 by from Works for ChIPThsi antibody Works well for Chip, for both cell culture and mouse livers.
Date published: 2019-05-07
Rated 5 out of 5 by from High Signal, no backgroundpPolII antibody was tested on 20µg murine Chromatin. Antibody detected the correct band with no backgorund. We use the antibody 1:1000. No complains!
Date published: 2018-04-19
Rated 3 out of 5 by from Clean but low signalI got a trail size of this antibody and tested it on Murine erythroleukemia cells (MEL). I got clean sharp bands on Western blot, but the signal was very low. I didn't quantify the amount of protein, but the minimum lysate required to see a signal was roughly equivalent to that from 150,000 cells. IMO for Pol II that's a lot!
Date published: 2018-02-23
Rated 4 out of 5 by from Work for HEK cells CHIP!It worked for HEK cells CHIP experiment! It actually worked!
Date published: 2018-02-14
  • y_2025, m_9, d_7, h_4
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_28
  • loc_ko_KR, sid_47701, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 8ms
  • REVIEWS, PRODUCT
Pol II 항체 (CTD4H8) is rated 4.4 out of 5 by 28.
  • y_2025, m_9, d_7, h_4
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_28
  • loc_ko_KR, sid_47701, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 114ms
  • REVIEWS, PRODUCT