Anti-myogenin Antibody (D-10) recommended for detection of myogenin of mouse, rat and human origin by WB, IP, IF and ELISA

Anti-myogenin Antibody (D-10): sc-13137

Anti-myogenin Antibody (D-10) is rated 4.8 out of 5 by 6.
  • y_2021, m_9, d_18, h_20
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.19
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_6
  • loc_en_US, sid_13137, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-3.2.0
  • CLOUD, getAggregateRating, 106ms
  • REVIEWS, PRODUCT
loading
5
5
4
1
3
0
2
0
1
0

Datasheets

    • myogenin Antibody (D-10) is a mouse monoclonal IgG3 κ, cited in 14 publications, provided at 200 µg/ml
    • raised against amino acids 1-225 of myogenin of human origin
    • recommended for detection of myogenin of mouse, rat and human origin by WB, IP, IF and ELISA
    • TransCruz reagent for Gel Supershift and ChIP applications (sc-13137 X, 200 µg/0.1 ml)
    • See myogenin (5FD): sc-52903 for myogenin antibody conjugates, including AC, HRP, FITC, PE, Alexa Fluor® 488, 594, 647, 680 and 790.
    • At present, we have not yet completed the identification of the preferred secondary detection reagent(s) for myogenin Antibody (D-10). This work is in progress.
loading

When should the TransCruz reagent sc-13137 X be used instead of the standard form sc-13137?

Asked by: cjMara
Thank you for your question. We recommend using the TransCruz reagent form when performing ChIP or GelShift assays. This form can also be used in other applications such as Western Blot or IHC, but the dilution should be adjusted by a factor of 10 to account for the higher original concentration.
Answered by: Technical Support
Date published: 2017-02-25
  • y_2021, m_9, d_18, h_20CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.19
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_13137, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-3.2.0
  • CLOUD, getContent, 107ms
  • QUESTIONS, PRODUCT
Rated 5 out of 5 by from Worked for flow cytometry using human muscle Worked for flow cytometry using human muscle extracts. -SCBT Publication Review
Date published: 2015-05-17
Rated 4 out of 5 by from Positive results in western blot analysis Positive results in western blot analysis of myogenin expression in SJRH30 whole cell lysate. -SCBT QC
Date published: 2015-03-29
Rated 5 out of 5 by from Strong bands observed in WB analysis of myogenin Strong bands observed in WB analysis of myogenin using murine MSCs. -SCBT Publication Review
Date published: 2015-03-09
Rated 5 out of 5 by from WB: clean bands observed at correct MW in WB: clean bands observed at correct MW in transfected lysates. -SCBT QC
Date published: 2015-03-01
Rated 5 out of 5 by from Produced beautiful immunofluorescence nuclear Produced beautiful immunofluorescence nuclear staining in methanol-fixed SJRH30 cells. -SCBT QC
Date published: 2015-02-09
Rated 5 out of 5 by from Published Western Blot data using human myoblast Published Western Blot data using human myoblast lysates. -SCBT Publication Review
Date published: 2015-01-12
  • y_2021, m_9, d_18, h_20
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.19
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_6
  • loc_en_US, sid_13137, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-3.2.0
  • CLOUD, getReviews, 13ms
  • REVIEWS, PRODUCT