    • GATA-2 Antibody (CG2-96) is a mouse monoclonal IgG1 κ, cited in 68 publications, provided at 200 µg/ml
    • raised against GATA-2
    • Anti-GATA-2 Antibody (CG2-96) is recommended for detection of GATA-2 of mouse, rat, human and avian origin by WB, IP and IF
    • Anti-GATA-2 Antibody (CG2-96) is available conjugated to agarose for IP; HRP for WB, IHC(P) and ELISA; and to either phycoerythrin or FITC for IF, IHC(P) and FCM
    • also available conjugated to Alexa Fluor® 488, Alexa Fluor® 546, Alexa Fluor® 594 or Alexa Fluor® 647 for WB (RGB), IF, IHC(P) and FCM, and for use with RGB fluorescent imaging systems, such as iBright™ FL1000, FluorChem™, Typhoon, Azure and other comparable systems
    • also available conjugated to Alexa Fluor® 680 or Alexa Fluor® 790 for WB (NIR), IF and FCM; for use with Near-Infrared (NIR) detection systems, such as LI-COR®Odyssey®, iBright™ FL1000, FluorChem™, Typhoon, Azure and other comparable systems
    • TransCruz reagent for Gel Supershift and ChIP applications (sc-267 X, 200 µg/0.1 ml)
    • Contact our Technical Service Department (or your local Distributor) for more information on how to receive a FREE 10 µg sample of GATA-2 (CG2-96): sc-267.
    • m-IgG Fc BP-HRP and m-IgG1 BP-HRP are the preferred secondary detection reagents for GATA-2 Antibody (CG2-96) for WB applications. These reagents are now offered in bundles with GATA-2 Antibody (CG2-96) (see ordering information below).
loading

Do you offer a small trial aliquot of this antibody?

Asked by: Martin Larke
Thank you for your question. Contact our Technical Service Department to arrange for a free 10 µg sample of our GATA-2 Antibody (CG2-96): sc-267.
Answered by: Tech Support Europe
Date published: 2019-06-04

When should the TransCruz reagent sc-267 X be used instead of the standard form sc-267?

Asked by: jenni
Thank you for your question. We recommend using the TransCruz reagent form when performing ChIP or GelShift assays. This form can also be used in other applications such as Western Blot or IHC, but the dilution should be adjusted by a factor of 10 to account for the higher original concentration.
Answered by: Technical Service 11
Date published: 2017-01-10
  • y_2022, m_1, d_19, h_20CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.20
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_267, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_scbt
  • bvseo_sdk, java_sdk, bvseo-3.2.0
  • CLOUD, getContent, 110ms
  • QUESTIONS, PRODUCT
Rated 4 out of 5 by from Good antibody I used GATA-2 for WB, the antibody diluted at 1:500 and incubated ON. I suggest use the secondary at dilution 1:20000 for 90min. I obtained good signal with little background noise.
Date published: 2021-04-29
Rated 5 out of 5 by from satisfied result We choose this antibody because it can gave us re-producable western blot result. We have been using it for years and work best compared to other brands.Our purpose is to create publishable data and this antibody is being used detect the GATA-2 expression in rat kidney tissue. GATA-2 was used to ensure that our CRISPR knockout worked and was validated using the antibody.It gave us saisfied result.
Date published: 2017-07-29
Rated 5 out of 5 by from nice quality We obtained best result for GATA-2 by WB,the antibody diluted at 1:600 and incubated 2hour at RT.We suggest use the secondary at dilution 1:5000.
Date published: 2017-07-02
Rated 5 out of 5 by from WB analysis Applied in WB to detect human lung cancer cells, dilution is 1:500, shows single and clear band.
Date published: 2017-05-13
Rated 5 out of 5 by from Strong western !! Nice western blot data; strong signal and low background
Date published: 2017-01-14
Rated 5 out of 5 by from Strong Western blot signal The GATA-2 Antibody (CG2-96) works very well for Western blot showing a strong signal with little to no background noise. This antibody has been cited well over 50 times.
Date published: 2016-12-28
Rated 1 out of 5 by from No superhift This antibody did not work in EMSA to super shift the GATA-2 band generated with K562 nuclear extract.
Date published: 2016-11-11
Rated 5 out of 5 by from Good in IP with HL Good in IP with HL-60 lysate -SCBT Publication Review
Date published: 2015-04-01